Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 16(5)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38475344

RESUMEN

The objective of this study is to evaluate the impact of the thickness and translucency of various computer-aided design/computer-aided manufacturing (CAD/CAM) materials on the polymerization of dual-cure resin cement in endocrown restorations. Three commercially available CAD/CAM materials-lithium disilicate glass (e.max CAD), resin composite (CERASMART), and a polymer-infiltrated ceramic network (ENAMIC)-were cut into plates with five different thicknesses (1.5, 3.5, 5.5, 7.5, and 9.5 mm) in both high-translucency (HT) and low-translucency (LT) grades. Panavia V5, a commercial dual-cure resin cement, was polymerized through each plate by light irradiation. Post-polymerization treatment was performed by aging at 37 °C for 24 h under light-shielding conditions. The degree of conversion and Vickers hardness measurements were used to characterize the polymerization of the cement. The findings revealed a significant decrease in both the degree of conversion and Vickers hardness with increasing thickness across all CAD/CAM materials. Notably, while the differences in the degree of conversion and Vickers hardness between the HT and LT grades of each material were significant immediately after photoirradiation, these differences became smaller after post-polymerization treatment. Significant differences were observed between samples with a 1.5 mm thickness (conventional crowns) and those with a 5.5 mm or greater thickness (endocrowns), even after post-polymerization treatment. These results suggest that dual-cure resin cement in endocrown restorations undergoes insufficient polymerization.

2.
Polymers (Basel) ; 15(8)2023 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-37111977

RESUMEN

Poly-ether-ether-ketone (PEEK) is commonly employed in dental prostheses owing to its excellent mechanical properties; however, it is limited by its low bond strength with dental resin cement. This study aimed to clarify the type of resin cement most suitable for bonding to PEEK: methyl methacrylate (MMA)-based resin cement or composite-based resin cement. For this purpose, two MMA-based resin cements (Super-Bond EX and MULTIBOND II) and five composite-based resin cements (Block HC Cem, RelyX Universal Resin Cement, G-CEM LinkForce, Panavia V5, and Multilink Automix) were used in combination with appropriate adhesive primers. A PEEK block (SHOFU PEEK) was initially cut, polished, and sandblasted with alumina. The sandblasted PEEK was then bonded to resin cement with adhesive primer according to the manufacturer's instructions. The resulting specimens were immersed in water at 37 °C for 24 h, followed by thermocycling. Subsequently, the tensile bond strengths (TBSs) of the specimens were measured; the TBSs of the composite-based resin cements after thermocycling were found to be zero (G-CEM LinkForce, Panavia V5, and Multilink Automix), 0.03 ± 0.04 (RelyX Universal Resin Cement), or 1.6 ± 2.7 (Block HC Cem), whereas those of Super-Bond and MULTIBOND were 11.9 ± 2.6 and 4.8 ± 2.3 MPa, respectively. The results demonstrated that MMA-based resin cements exhibited stronger bonding to PEEK than composite-based resin cements.

3.
Dent Mater J ; 42(3): 327-335, 2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-36709988

RESUMEN

Phosphoric acid (PA) etchants are widely used for the bonding pretreatment of teeth; however, their influences on the bonding between glass-ceramics and resin cement have not been clarified yet. This study investigated the effect of a thickening agent on the bonding strength between feldspar porcelain treated with a PA etchant and resin cement with a silane coupling agent. The experiments were performed using two PA etchants: commercial one and prepared one consisting a PA aqueous solution and poly(ethylene glycol) thickening agent. The samples were evaluated by shear bond strength testing, scanning electron microscopy, and Fourier-transform infrared spectroscopy. The obtained results revealed that the thickening agent adhered to the porcelain surface and inhibited cement bonding. Meanwhile, PA remained on the surface due to the presence of the thickening agent and activated the silane coupling agent. Overall, the PA etchant did not improve the bond durability.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Cementos de Resina/química , Silanos/química , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Cerámica/química , Ensayo de Materiales , Resistencia al Corte
4.
J Prosthodont Res ; 67(1): 132-137, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-35431286

RESUMEN

Purpose Hydrofluoric acid has been used to remove salivary contamination in dental glass-ceramics before bonding treatment. However, alternative methods are required because hydrofluoric acid is harmful. This study examined the cleaning effects of phosphoric acid and sodium hydroxide on glass-ceramics for bonding pre-treatment.Methods Feldspar porcelain was divided into four groups: (C) cleaned porcelain without any contamination, (S) porcelain contaminated with saliva, (SPA) porcelain cleaned with 37% phosphoric acid after saliva contamination, and (SSH) porcelain cleaned with 10% sodium hydroxide after saliva contamination. Each sample was bonded to the resin cement using a silane-containing primer. They were then subjected to a shear bond strength (SBS) test. Each surface was analyzed by scanning electron microscopy (SEM), contact angle measurements, and Fourier transform infrared spectroscopy (FT-IR).Results The SBS of group SSH was comparable to that of group C but significantly higher than that of groups S and SPA. SEM observations showed that saliva-like structures remained on the samples of groups S and SPA, but not on the SSH group. The contact angles of groups C and SSH were comparable and significantly smaller than those of groups S and SPA, respectively. FT-IR analysis also revealed saliva in groups S and SPA, which was absent in the SSH group.Conclusions The saliva remained on the porcelain even after cleaning with phosphoric acid, and SBS was not restored to the same level as before the contamination. In contrast, sodium hydroxide eliminated saliva and restored SBS to the same level as before contamination.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Porcelana Dental/química , Saliva , Hidróxido de Sodio , Ácido Fluorhídrico , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales , Resistencia al Corte , Análisis del Estrés Dental
5.
J Mech Behav Biomed Mater ; 105: 103708, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32090894

RESUMEN

This study aims to develop a corona discharge process for a surface treating a glass-ceramic, feldspar porcelain, to improve its bonding to a resin cement with a silane-coupling agent. Corona discharge, a type of plasma process, was performed using a custom-made device on a porcelain surface at temperatures ranging from 25 to 300 °C, for specific treatment times in air. The porcelain was then subjected to a post-heat-treatment at 600 °C to condition the surface state. The resulting surface was primed with a silane-coupling-agent followed by cementing using a resin cement to measure the shear bond strength (SBS). To investigate the effect of surface modifications by the corona discharge treatment, the porcelain was characterized by surface roughness, contact angle, and an X-ray photoelectron spectroscopy analyses. The SBS for the corona-discharge-treated porcelain increased with an increase in treatment-temperature and -time, and reached the maximum value at 200 °C and 5 min. The post-heat-treatment improved the bond durability after thermocycling. The SBS for the corona-discharge-treated porcelain was then compared to that of a conventional hydrofluoric-acid-treated one, which showed that the SBSs were comparable. The results of the surface characterizations indicated that the corona discharge treatment generated silanol groups on the porcelain surface giving hydrophilic properties without roughening the surface. It was found that the corona discharge treatment generates silanol groups on the porcelain surface, resulting in an increased SBS. This study is the first to demonstrate that corona discharge treatment is effective for improving bond strength through the modification of the surface of glass-ceramics.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Silicatos de Aluminio , Cerámica , Porcelana Dental , Análisis del Estrés Dental , Ensayo de Materiales , Compuestos de Potasio , Resistencia al Corte , Silanos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...